Preventive Maintenance of Vibro Sifter

0

 

Preventive Maintenance of Vibro Sifter

 

1.0         Purpose

 1.1       To lay down a procedure for the Preventive Maintenance of Vibro Sifter.


2.0         Scope 

2.1          This procedure is applicable for the Preventive Maintenance of Vibro Sifter at “NAME” Pharmaceuticals

Ltd. 

 

3.0      Responsibility 

3.1.    Only trained Technician is responsible for normal operation. He/ She inform the   supervisor about            any deviation from normal operation. He also maintains logbook.

3.2.       Head of Engineering and Maintenance shall be responsible for the implementation of this SOP.

3.3        Head of QA / designee shall be responsible for compliance of this SOP.

 

4.0      Abbreviations and Definitions

4.1        SOP     :           Standard Operating Procedure.

4.2        QA       :           Quality Assurance

 

5.0       Materials and Equipment

5.1        None

 

6.0      Precaution / Health and Safety Considerations

6.1        None

 

7.0       Procedure

7.1.         Before carried out the preventive maintenance, Switch off the incoming power supply and display “Under Maintenance”.

7.2.         The Technician has to ensure and verify the check points for the preventive maintenance as shown in the Annexure-I.

7.3.         After the completion of preventive maintenance, check the machine for smooth operation.

7.4.         Remove “Under Maintenance”

7.5.         The Technician perform the job will enter his name / sign in “Done by” column and responsible Engineer / Officer will put sign in “Checked By” column.

7.6.         Preventive Maintenance is carried out monthly as per the following check points:

7.6.1     Check rugged spring for proper tightness, rectify if any abnormally.

7.6.2     Check dead weight for proper fitting

7.6.3     Lubricate the motor bearings.

7.6.4     Check wheels for free movement and it should lock proper if any abnormalities rectify it.

7.6.5     Check motor electrical terminals for proper tightness.

7.6.6     Check all gaskets for any damage, replace if required.

7.6.7     Check operation sifter for proper vibration adjust the dead weight.

 

8.0      Reference Document

8.1        In-House,

 

9.0       Annexure     

9.1        Annexure –I      :           Preventive Maintenance Checklist of Vibro Sifter

 

10.0    Revision History 

Revision No.

Brief reason for the revision

   Effective Date

   Remarks

01

New

 

 

 

11.0    Training

11.1      Head of Engineering and Maintenance or his nominee give the training of Technician and Operators .

 

Annexure-I 

Preventive Maintenance Checklist of Vibro Sifter 

Area :

 

Date:

 

Equipment No :

 

Frequency:

Monthly

 

Sl. No.

Description of the Job

Observation

Corrective Action

Spared Used

1.

Switch off the machine and remove the plug pin from the socket

Š Ok  /  Š Not Ok

 

 

2.

Put “Under Maintenance” Board on switchboard.

Š Ok  /  Š Not Ok

 

 

3.

Check rugged spring for proper tightness, rectify if any abnormally.

Š Ok  /  Š Not Ok

 

 

4.

Check dead weight for proper fitting

Š Ok  /  Š Not Ok

 

 

5.

Lubricate the motor bearings.

Š Ok  /  Š Not Ok

 

 

6.

Check wheels for free movement and it should lock proper if any abnormalities rectify it.

Š Ok  /  Š Not Ok

 

 

7.

Check motor electrical terminals for proper tightness.

Š Ok  /  Š Not Ok

 

 

8.

Check all gaskets for any damage,

Š Ok  /  Š Not Ok

 

 

9.

Check operation sifter for proper vibration adjust the dead weight.

Š Ok  /  Š Not Ok

 

 

 

  

………………………………….

Done By

 

………………………………….

Checked By

 

 

 

 

 

 

 

Post a Comment

0Comments

Post a Comment (0)