1.0 Purpose
1.1 To lay down a procedure for the Preventive Maintenance of Vibro Sifter.
2.0
Scope
2.1 This procedure is applicable for the Preventive Maintenance of Vibro Sifter at “NAME” Pharmaceuticals
Ltd.
3.0 Responsibility
3.1. Only trained Technician is responsible for
normal operation. He/ She inform the supervisor
about any deviation from normal
operation. He also maintains logbook.
3.2. Head of Engineering and Maintenance shall
be responsible for the implementation of this SOP.
3.3 Head of QA / designee shall be
responsible for compliance of this SOP.
4.0 Abbreviations and Definitions
4.1 SOP : Standard Operating Procedure.
4.2 QA : Quality Assurance
5.0 Materials and Equipment
5.1 None
6.0 Precaution / Health and Safety Considerations
6.1 None
7.0 Procedure
7.1. Before carried out the preventive maintenance, Switch off the incoming power supply and display “Under Maintenance”.
7.2. The Technician has to ensure and verify the check points for the preventive maintenance as shown in the Annexure-I.
7.3. After the completion of preventive maintenance, check the machine for smooth operation.
7.4. Remove “Under Maintenance”
7.5. The Technician perform the job will enter his name / sign in “Done by” column and responsible Engineer / Officer will put sign in “Checked By” column.
7.6. Preventive Maintenance is carried out monthly as per the following check points:
7.6.1 Check rugged spring for proper tightness, rectify if any abnormally.
7.6.2 Check dead weight for proper fitting
7.6.3 Lubricate the motor bearings.
7.6.4 Check wheels for free movement and it should lock proper if any
abnormalities rectify it.
7.6.5 Check motor electrical terminals for proper tightness.
7.6.6 Check all gaskets for any damage, replace if required.
7.6.7 Check operation sifter for proper vibration adjust the dead
weight.
8.0 Reference Document
8.1 In-House,
9.0 Annexure
9.1 Annexure –I : Preventive Maintenance Checklist of Vibro Sifter
10.0 Revision History
Revision
No. |
Brief reason for the revision |
Effective Date |
Remarks |
01 |
New |
|
|
11.0 Training
11.1 Head of Engineering and Maintenance or his nominee give the training of Technician and Operators .
Annexure-I
Preventive Maintenance Checklist of Vibro Sifter
Area : |
|
Date: |
|
Equipment
No : |
|
Frequency: |
Monthly |
Sl. No. |
Description
of the Job |
Observation |
Corrective
Action |
Spared
Used |
|
1. |
Switch off the machine and remove the plug
pin from the socket |
Ok /
Not Ok |
|
|
|
2. |
Put “Under Maintenance” Board on switchboard. |
Ok /
Not Ok |
|
|
|
3. |
Check rugged spring for proper tightness,
rectify if any abnormally. |
Ok /
Not Ok |
|
|
|
4. |
Check dead weight for proper fitting |
Ok /
Not Ok |
|
|
|
5. |
Lubricate the motor bearings. |
Ok /
Not Ok |
|
|
|
6. |
Check wheels for free movement and it should
lock proper if any abnormalities rectify it. |
Ok /
Not Ok |
|
|
|
7. |
Check motor electrical
terminals for proper tightness. |
Ok /
Not Ok |
|
|
|
8. |
Check all gaskets for any
damage, |
Ok /
Not Ok |
|
|
|
9. |
Check operation sifter for
proper vibration adjust the dead weight. |
Ok /
Not Ok |
|
|
|
|
|||||
…………………………………. Done By |